NEM batteries transitioned to bidirectional units in 2024

Scheduled batteries as separate generation and load units transitioned to bidirectional units (BDUs) in 2024.

The transitions came with the changes made for integrating energy storage systems into the NEM.

The following table presents the day each battery system transitioned, the Cutover. We’ve set this as the day when the new bidirectional unit had non-zero availability (was first available for dispatch).

As many readers would recall, the transition process included an overlap period where each battery’s outgoing load/gen units would be present in dispatch alongside the incoming BDU for a period while the transition was underway. Then, at a specific interval on the cutover day the outgoing units would be bid unavailable and the new BDU would be eligible to be bid available.

This was discussed in When will we start seeing BDUs in dispatch? and First Bidirectional Units on 4th July 2024.

Units typically cut over to their BDU counterpart in 2 weeks once the BDU was registered

Station Name Gen DUID Load DUID BDU BDU
Registered
Cutover Gen & Load
Deregistered
Broken Hill Battery BHBG1 BHBL1 BHB1 2024-07-04 2024-07-16 2024-07-26
Wandoan BESS WANDBG1 WANDBL1 WANDB1 2024-07-04 2024-07-16 2024-07-26
Torrens Island BESS TIBG1 TIBL1 TIB1 2024-07-12 2024-07-24 2024-07-31
Dalrymple North BESS DALNTH01 DALNTHL1 DALNTH1 2024-07-12 2024-07-24 2024-07-31
Riverina Energy Storage System 2 RIVNBG2 RIVNBL2 RIVNB2 2024-07-18 2024-08-06 2024-08-14
Darlington Point BESS DPNTBG1 DPNTBL1 DPNTB1 2024-07-18 2024-08-06 2024-08-14
Ballarat BESS BALBG1 BALBL1 BALB1 2024-07-18 2024-08-06 2024-08-14
Gannawarra BESS GANNBG1 GANNBL1 GANNB1 2024-07-18 2024-08-06 2024-08-14
Queanbeyan BESS QBYNBG1 QBYNBL1 QBYNB1 2024-08-09 2024-08-21 2024-08-28
Hazelwood BESS HBESSG1 HBESSL1 HBESS1 2024-08-15 2024-08-27 2024-09-04
Phillip Island BESS PIBESSG1 PIBESSL1 PIBESS1 2024-08-15 2024-08-27 2024-09-04
Adelaide Desalination Plant ADPBA1G ADPBA1L ADPBA1 2024-09-06 2024-09-18 2024-10-02
Bolivar Waste Water Treatment (WWT) Plant BOWWBA1G BOWWBA1L BOWWBA1 2024-09-06 2024-09-18 2024-10-02
Christies Beach Waste Water CBWWBA1G CBWWBA1L CBWWBA1 2024-09-06 2024-09-18 2024-10-02
Happy Valley Waste Water HVWWBA1G HVWWBA1L HVWWBA1 2024-09-06 2024-09-20 2024-10-02
Hornsdale Power Reserve HPRG1 HPRL1 HPR1 2024-09-12 2024-09-24 2024-10-02
Capital BESS CAPBES1G CAPBES1L CAPBES1 2024-09-12 2024-09-24 2024-10-02
Vic Big Battery VBBG1 VBBL1 VBB1 2024-09-13 2024-10-02 2024-10-09
Bulgana Green Energy Hub BULBESG1 BULBESL1 BULBES1 2024-09-13 2024-10-02 2024-10-09
Lake Bonney BESS LBBG1 LBBL1 LBB1 2024-09-26 2024-10-08 2024-10-16
Wallgrove BESS WALGRVG1 WALGRVL1 WALGRV1 2024-09-26 2024-10-08 2024-10-16
Bouldercombe Battery Project BBATTERY BBATRYL1 BBATTERY1 2024-10-04 2024-10-16 2024-10-23
Riverina BESS RESS1G RESS1L RESS1 2024-10-10 2024-10-29 2024-11-06
Chinchilla BESS CHBESSG1 CHBESSL1 CHBESS1 2024-10-18 2024-10-31 2024-11-06
Western Downs BESS WDBESSG1 WDBESSL1 WDBESS1 2024-11-14 2024-11-26 2024-12-04
Tailem Bend 2 BESS TB2BG1 TB2BL1 TB2B1 2024-11-21 2024-12-03 2024-12-11

New batteries registered as bidirectional units.

Now that batteries must be bidirectional units, the new batteries starting out as bidirectional units in 2024 were:

  • Blyth BESS on 20 August 2024,
  • Greenbank BESS on 17 December 2024,
  • Rangebank BESS on 13 August 2024,
  • Waratah Super Battery on 3 September 2024.

During the transition period measures like max capacity appear twice

The battery is represented twice in registration data over the transition period. Due to this overlap, without careful treatment, measures like max capacity risk being double counted. The overlap covers the time from when the BDU was registered, until the time the old Gen/Load units are deregistered.

That’s why we also present the day when the BDU was registered and the day when the old Gen/Load units were de-registered in the above table.

 


About the Author

Linton Corbet
Linton is a Senior Software Engineer and Market Analyst, who joined Global-Roam in August 2020. Before joining the company, Linton worked at the Australian Energy Market Operator (AEMO) for seven years, including four years as an analyst within their demand forecasting team. Before entering the energy sector, he worked as an air quality scientist in the Czech Republic.