A Queensland case study into what household data from the 15th of January 2026 tells us about home battery price responsiveness

There is growing interest in the effects of increased battery uptake in the wake of the Australian Government’s Cheaper Home Batteries Program. The explosive nature of the growth in batteries being installed is exemplified below in an excerpt from the Clean Energy Council’s Rooftop solar and storage report for July to December 2025.

Total Battery Installations, quarterly. CEC, 2026.

Broad trends of the demographics of these new battery owners are visible with public data, but this article presents an investigation into the effects of batteries on household import and export behaviour. Aggregated and anonymised smart meter data of Queensland domestic customers (with no ability to identify individual customers or premises), both with and without solar and with differing battery sizes was used. Customers were compared based on whether they were supplied by major ‘typical’ energy retailers, or those retailers that provide some degree of wholesale spot price exposure.

The aim here was not to draw conclusions about which battery size, operation mode or type of retailer delivers the best outcomes, but rather an exploratory and observational exercise to reveal what distinct behaviours can already be observed among household battery owners.

What happened on the 15th of January 2026?

Thursday the 15th of January 2026 was one of many hot days that month in Queensland, with the temperature reaching 31.5°C in Brisbane city. What makes this day notable is that it was one of the few evening over summer 2025/26 where extreme price spikes occurred, with the wholesale price briefly exceeding $1,000/MWh over multiple periods. The maximum dispatch price set in QLD that evening was $19,728/MWh – almost $20 per kilowatt-hour in the units that households are more familiar with on their electricity bills. These conditions provide a useful ‘stress-test’ environment to examine whether, and to what extent, households with batteries can respond to price signals.

Methodology

Customer-level smart meter data was sourced from an internal dataset containing 288 five-minute readings per customer, per day for both exported and imported energy and combined with corresponding 5-minute wholesale spot prices from AEMO. Also included was any available data about registered batteries, including their capacity and install date.

Customers were divided into two groups based on either being customers of a major Queensland electricity retailer, or a retailer offering spot price exposure. They were then further segmented based on battery capacity: ≥ 30 kWh, 15–30 kWh, < 15 kWh, and No Battery Data (customers with no recorded battery capacity). Customers without a recorded installation date were excluded from the analysis. Note that this retailer classification did not discriminate whether customers were part of a Virtual Power Plant (VPP) program.

For each battery category, the twelve 5-minute intervals within each clock hour (0–23) were summed to produce hourly energy totals per customer. Four summary statistics were then calculated across all customers in each category for every hour: the mean, the median (50th percentile), and the 25th and 75th percentiles (bounding the interquartile range), computed separately for both exported and imported energy. Export values are presented as negative (energy flowing to grid) to visually distinguish them from import (energy drawn from grid). Lines are wrapped from hour 0 to 24 to visually close the daily profile.

The time-of-use windows are highlighted: evening peak (4 pm–9 pm) and daytime off-peak (11 am–4 pm) (aligned with our default domestic network tariff). The 5-minute wholesale spot prices are overlaid on the energy profiles with scale shown on the right-hand-side axis. Note that the price axis is capped at the 95th percentile of absolute price values to maintain readability; markers indicate price spikes that exceed the visible range, such as when the price briefly reached $19.73 per kWh just before 7pm!

Results – Baseline for Customers with Major Retailers

Across the major Queensland retailers, January 15th produces an expected residential solar ‘duck curve’. Around 93% of customers in this dataset have no registered battery. Their midday export is moderate (1 to 2 kWh/hr at the median), and evening imports rise predictably to 0.8 to 1.2 kWh/hr as households resume consumption after the sun sets.

The remaining 7% who do have batteries represent an approximate total installed capacity of 1.4 GWh: approximately 609 MWh in the ≥ 30 kWh category, 463 MWh in the 15 to 30 kWh category, and 351 MWh in the < 15 kWh category. Battery-equipped major retailer customers on average behave similarly to those without, but the median major retailer customer with a battery has an evening import of close to 0kW. This highlights the value of batteries in negating a household’s contribution to evening peak demand. The evening import profile rises in broadly the same shape regardless of battery size. This group’s average export profile during the evening indicates that the battery supports self-consumption, minimising imports until discharged, rather than actively chasing export prices.

Spot Price Exposed Customers

The spot-price exposed group tells a very different story, starting with its composition: 52% have registered battery systems, compared to just 7% for major retailers. This represents an estimated total installed capacity based on available data of 161 MWh: around 92 MWh in the ≥ 30 kWh category, 46 MWh in the 15 to 30 kWh category, and 22 MWh in the < 15 kWh category. While a fraction of the major retailer fleet in absolute terms, the per-customer battery size is comparable, and the concentration of battery customers is roughly 7 times higher.

Another notable feature is the divergence between average and median export: averages sit well below medians across all battery categories, revealing a tail of heavily optimised customers who export at very high rates and push the average export significantly higher than what’s typical.

Evening Peak: Biggest Contrast

January 15th saw spot prices spike from around $27/MWh to nearly $19,728/MWh, with the most extreme prices clustering between 5 and 7pm. This is where the difference between the two groups is most obvious.

Spot-exposed ≥ 30 kWh battery customers sustain significant net export through the evening peak. These customers actively discharge stored solar back into the grid during the most valuable window. Median export continues through 5 to 7pm, meaning more than half of these customers are sending energy to the grid at the exact hours the system needs it most. The average is pulled even lower into export territory, likely by a tail of heavily optimised households with the most responsive use schedules.

Major retailer ≥ 30 kWh battery customers show virtually none of this behaviour. Despite having comparable installed capacity per customer, their evening export is negligible. Batteries in this group appear to only absorb midday solar and release it back into the household later, rather than dispatching into the grid when wholesale prices spike.

In Summary

This case study shows that household battery behaviour is shaped by a combination of system size and ability to respond to price signals. Larger batteries allow households to reduce evening grid use for longer, but spot-price exposure also influences when and how those batteries are used. Customers on spot pricing retail plans are more likely to have batteries, export more power during the day, sharply reduce grid import and export significantly during high‑price evening periods. Similar patterns are not observed among most major retailer customers, even when battery sizes are comparable.

Behaviour also varies widely within the spot‑exposed group. A smaller number of highly engaged households account for much of the strongest response, reflecting differences in battery size, automation, and household choices. Overall, the results suggest that battery capacity and price signals work together to shape outcomes, particularly during evening peaks. As battery uptake continues to grow, both the scale of battery installations themselves and how customers are empowered to benefit from them will influence impacts on the grid and the market.

 

Join the conversation on LinkedIn?

Editor’s Note:  Readers here might like to engage in the conversation that is ensuing over on LinkedIn here, with respect to the analysis Emma presents in her article here on WattClarity.

 

Acknowledgements: This analysis builds on work presented by Energex and Ergon Energy Network at the Solar & Storage Live Queensland 2026 conference, with thanks to Peter Kilby for presenting and his assistance with this work.

Disclaimer: The views expressed in this article are those of the author and are not intended to represent formal positions of Energex or Ergon Energy Network. Analysis is provided for information purposes only and does not constitute policy, regulatory or commercial advice.


About our Guest Author

Emma Dyson is a Graduate Engineer at Energex and Ergon Energy Network, currently developing her skills and gaining experience across Queensland’s distribution network.

She holds a Bachelor of Engineering (Electrical) from Queensland University of Technology and is passionate about supporting Australia’s energy transition.

You can find Emma on LinkedIn here.



Leave a comment

Your email address will not be published.


*